On the Network+ · 24% of Network+ N10-009 (Domain 5 — largest domain)
Symptom-plus-CLI-output multiple-choice items and multi-device PBQs requiring root-cause isolation across Layers 1–7 and CompTIA's 7-step methodology.
What Network Troubleshooting tests
Network Troubleshooting is the largest domain on CompTIA Network+ N10-009. Questions hand you user symptoms alongside switch counters, cable test results, or terminal outputs (ipconfig/ip, ping, traceroute/mtr, arp -a, nslookup/dig, netstat/ss, tcpdump, show mac address-table, show ip route) and ask either for the root cause or the exact NEXT step in CompTIA's 7-step troubleshooting model.
Where test-takers lose points
Jumping ahead in CompTIA's 7-step network troubleshooting methodology
The 7 steps run in strict order: (1) Identify the problem, (2) Establish a theory of probable cause, (3) Test the theory to determine cause, (4) Establish a plan of action and identify potential effects, (5) Implement the solution or escalate, (6) Verify full system functionality and implement preventive measures, (7) Document findings, actions, and outcomes.
Misreading APIPA (169.254.x.x) versus default-gateway or DNS failures
A 169.254.x.x address proves the host never completed DHCP DORA (check physical link, wrong switch access VLAN, exhausted DHCP pool, or missing DHCP relay). If the host has a valid subnet IP and ping 1.1.1.1 succeeds while ping app.corp.local fails, Layer 1–3 routing is working and DNS is broken.
Confusing duplex mismatch counters with MTU / MSS black-hole symptoms
Hardcoding one interface to 100/Full while leaving its partner on Auto drops the auto side to 100/Half, generating late collisions on the half-duplex end and FCS/CRC errors with crippled upload/download symmetry. If small ping packets pass over a VPN tunnel while HTTPS pages or large transfers stall, suspect an MTU black hole (DF bit set without TCP MSS clamping).
How to practise Network Troubleshooting
Troubleshoot bottom-up (Layer 1 link lights/CRC/TDR → Layer 2 VLAN/MAC/STP/ARP → Layer 3 IP/mask/gateway/route/MTU → Layer 4 ACL/port → Layer 7 DNS/application) unless a symptom already proves lower layers work—if ping to a remote IP works, never waste time testing patch cables.
Common questions about Network+ Network Troubleshooting
When should a technician grab a TDR instead of an OTDR?
Use a Time Domain Reflectometer (TDR) to measure distance to opens, shorts, or severe crimps on copper twisted-pair/coax runs; use an Optical Time Domain Reflectometer (OTDR) to pinpoint breaks, splice loss, or sharp macro-bends along fiber-optic cables.
What causes high giants versus runts on a switch interface counter?
Runts are Ethernet frames smaller than the 64-byte minimum (typically from half-duplex collisions or bad NICs), whereas giants exceed 1,518 bytes (1,522 with 802.1Q)—commonly caused by hosts sending 9,000-byte Jumbo Frames into a switch port where Jumbo Frames are not enabled.
How do traceroute (Linux/macOS) and tracert (Windows) differ under the hood?
Both increment IP TTL starting at 1 to elicit ICMP Time Exceeded replies from each hop, but Windows tracert sends ICMP Echo Requests by default while Linux/Unix traceroute sends high-port UDP probes unless switched to -I (ICMP) or -T (TCP).
10 example questions with full explanations. Use the interactive practice above to work through the complete set.
Question 1hard
File transfers across a 100BASE-TX copper link between `SW-Floor2` and a legacy branch router crawl below 2 Mbps, although low-rate pings succeed. Interface counters show:
- `SW-Floor2 Gi0/24`: `Half-duplex, 100Mb/s`, `48,912 late collisions`, `0 CRC`
- `Router Fa0/1`: `Full-duplex, 100Mb/s`, `51,204 input errors`, `50,988 CRC`
What is the MOST likely root cause?
- A.Jumbo 9000-byte MTU enabled on user laptops while Router Fa0/1 enforces 1500 bytes
- B.Duplex mismatch (hardcoded Full on router, Auto fallback to Half on switch)✓
- C.Spanning Tree reconverging Gi0/24 every 2 seconds because Hello BPDUs are blocked
- D.Modal dispersion from patching an OM1 multimode jumper into a single-mode optic
Correct answer: B
When one 100BASE-TX peer is hardcoded to `100/Full` (disabling autonegotiation) and the switch is left on `auto`, parallel detection senses 100 Mbps speed but defaults to `Half-duplex`. The Full-duplex router transmits without CSMA/CD carrier deferral, causing late collisions on the Half-duplex switch and truncated/corrupted frames (CRC/FCS errors) on the Full-duplex router (Option B). Option D cites fiber optics on copper, Option C cites STP flapping, and Option A would produce giants rather than late collisions.
Question 2hard
Branch users traversing a new GRE-over-IPsec tunnel (`MTU 1400`) can `ping 10.1.5.20` with default 32-byte payloads and complete TCP 443 handshakes to the headquarters ERP portal, yet web pages stall blank whenever large TLS records transfer, and `ping -f -l 1472 10.1.5.20` times out. A strict core firewall drops all ICMP Type 3 messages. What explains these symptoms and resolves the TCP stalls?
- A.Duplicate ERP server IP address; flush switch ARP caches and shorten DHCP leases
- B.Path MTU black hole; clamp TCP MSS to 1360 bytes and allow ICMP Type 3 Code 4✓
- C.Split-horizon DNS loop; publish an internal AAAA record for 10.1.5.20 at the branch
- D.Half-open SYN flood protection; disable stateful TCP inspection on both VPN peers
Correct answer: B
A 1472-byte ICMP payload (+ 20 IP + 8 ICMP = 1500 bytes) or standard 1460-byte TCP MSS segment with the Don't Fragment (`DF`) bit set exceeds the 1400-byte GRE/IPsec tunnel MTU. Dropping ICMP Type 3 Code 4 (*Fragmentation Needed and DF Set*) breaks Path MTU Discovery (PMTUD), creating an MTU black hole where small pings/SYNs pass and full segments vanish; clamping TCP MSS (e.g., `1360` bytes) and permitting ICMP Type 3 Code 4 fixes it (Option B). Option A, Option D, and Option C fail to explain payload-size sensitivity.
Question 3hard
After adding a backup MPLS router (`Rtr-MPLS`), outbound TCP `SYN` packets from `10.20.1.50` to `10.80.1.10` take `Rtr-MPLS` directly (bypassing stateful firewall `FW-1`), whereas return `SYN-ACK` packets from `10.80.1.10` route through `FW-1`. Every TCP session fails, and `FW-1` logs `Deny TCP (no connection) flags SYN ACK`. Why is `FW-1` dropping the replies?
- A.Asymmetric routing bypassed FW-1 on the SYN, leaving no state entry for SYN-ACK✓
- B.Rtr-MPLS decrements the outbound IPv4 Time-to-Live field to zero before delivery
- C.Server 10.80.1.10 transmitted its SYN-ACK from an ephemeral source port above 49152
- D.TCP window scaling fails whenever MPLS and firewall links run at unequal speeds
Correct answer: A
Stateful firewalls permit return `SYN-ACK` segments only when a matching outbound `SYN` first created a session entry in the firewall state table. Because asymmetric routing steered the outbound `SYN` through `Rtr-MPLS` around `FW-1`, `FW-1` treats the returning `SYN-ACK` as unsolicited out-of-state traffic and drops it (Option A). Option B contradicts `SYN-ACK` generation, while Option D and Option C misstate TCP behavior.
Question 4medium
A newly imaged desktop can `ping` its local department NAS (`10.30.5.12`) and network printer (`10.30.5.40`), but cannot `ping 8.8.8.8` or reach internal servers in other VLANs. `ipconfig` displays:
- IPv4 Address: `10.30.5.88`
- Subnet Mask: `255.255.255.0`
- Default Gateway: `10.30.50.1`
- DNS Server: `10.10.1.53`
What is causing the off-subnet connectivity failure?
- A.Switch access-port VLAN mismatch isolating the desktop from VLAN 10.30.5.0/24
- B.Unresponsive DNS forwarder at 10.10.1.53 failing to resolve external hostnames
- C.Classful /24 mask overlapping with RFC 3927 APIPA link-local address space
- D.Default gateway 10.30.50.1 sits outside 10.30.5.0/24✓
Correct answer: D
With IP `10.30.5.88` and mask `255.255.255.0` (`/24`), the desktop's local subnet spans `10.30.5.1` through `10.30.5.254`. Same-subnet ARP reaches `.12` and `.40`, whereas default gateway `10.30.50.1` has a typo in the third octet (`50` instead of `5`), leaving the host with no reachable on-link router for remote subnets (Option D). Option A is disproved by local pings, Option B is disproved by raw IP ping failure, and Option C confuses RFC 1918 with APIPA.
Question 5easy
From a branch workstation, `ping 1.1.1.1` succeeds in 12 ms and `tracert 9.9.9.9` completes cleanly in 6 hops, yet `nslookup portal.corp.example` times out against `10.99.99.53` and browsers fail to open websites by URL. Which failure explains this output?
- A.DHCP pool exhaustion forcing the workstation onto an unroutable 169.254.x.x IP
- B.Port security err-disable shutdown triggered on the workstation's switch interface
- C.Missing default `0.0.0.0/0` route inside the branch edge router forwarding table
- D.DNS server 10.99.99.53 is unreachable or misconfigured✓
Correct answer: D
End-to-end IP reachability to `1.1.1.1` and `9.9.9.9` verifies Layers 1 through 3 (NIC, VLAN, gateway, NAT, and WAN routing), while `nslookup` timing out against `10.99.99.53` isolates the fault to Layer 7 DNS name resolution (wrong DNS IP, blocked UDP/TCP 53, or down DNS service) (Option D). Option C, Option B, and Option A would all break IP-based ping and traceroute.
Question 6medium
Newly patched workstation `PC-Acct4` on `SW3` port `Gi0/15` self-assigns `169.254.84.19`, whereas other accounting PCs in VLAN 50 on `SW3` obtain `10.50.0.x` DHCP leases normally. `show vlan brief` on `SW3` lists `Gi0/15` under `VLAN 500`, and `show interfaces trunk` shows `Vlans allowed on trunk: 10,20,50,99`. What is the root cause?
- A.BPDU Guard placing interface Gi0/15 into an err-disabled shutdown state
- B.Exhausted DHCP address pool inside the accounting 10.50.0.0/24 server scope
- C.Port Gi0/15 is misassigned to unrouted VLAN 500 instead of VLAN 50✓
- D.Open wire pair in the Cat6 patch cord preventing Layer 1 link-up on Gi0/15
Correct answer: C
A typo placed `Gi0/15` into `VLAN 500` rather than `VLAN 50`; because `VLAN 500` is not even permitted across the uplink trunk (`10,20,50,99`), `DHCPDISCOVER` broadcasts stay trapped locally and `PC-Acct4` falls back to `169.254.84.19` APIPA (Option C). Option B blames a scope `Gi0/15` never reaches, while Option D and Option A contradict active link-up.
Question 7medium
Following the CompTIA 7-step network troubleshooting methodology, an engineer identified choppy VoIP audio symptoms, formed a theory that a distribution uplink was remarking `DSCP EF` packets to `0`, and verified via packet capture that the theory is confirmed. Which step comes IMMEDIATELY NEXT?
- A.Push updated QoS trust commands straight to all core switches during peak hours
- B.Record final resolution notes, outcomes, and lessons learned in the ticket log
- C.Establish a plan of action to resolve the problem and identify potential effects✓
- D.Interview unaffected departments to gather initial symptom descriptions again
Correct answer: C
CompTIA's 7-step troubleshooting sequence runs: (1) Identify the problem, (2) Establish a theory of probable cause, (3) Test the theory to determine the cause, (4) Establish a plan of action to resolve the problem and identify potential effects, (5) Implement the solution or escalate, (6) Verify full system functionality and preventive measures, and (7) Document findings, actions, outcomes, and lessons learned. After confirming the theory in Step 3, Step 4 comes next (Option C), before Step 5 implementation (Option A) or Step 7 documentation (Option B), while Step 1 (Option D) is already complete.
Question 8medium
After roadside excavation near a 4 km buried single-mode fiber run between two campus buildings, both switches report `LOS` (Loss of Signal). Which diagnostic instrument injects laser pulses into one end of the fiber and measures backscatter/reflections to report the exact distance in meters to the cut?
- A.Metallic Time-Domain Reflectometer (TDR) transmitting electrical voltage steps
- B.Inductive tone generator and amplifier wand tracing cables across punchdown blocks
- C.Optical power meter and light source measuring end-to-end dBm insertion loss
- D.Optical Time-Domain Reflectometer (OTDR)✓
Correct answer: D
An Optical Time-Domain Reflectometer (OTDR) launches timed optical pulses down a fiber strand and analyzes Rayleigh backscatter and Fresnel reflections to plot splice losses and pinpoint the exact distance to a break (Option D). Option A and Option B test metallic copper only, and Option C measures total end-to-end dB loss rather than distance to a fault.
Question 9medium
Employees report that browsing to intranet server `10.15.2.10` loads the HR portal for a few minutes, then suddenly displays a laser-printer status page or resets TCP connections. On the core switch, `show ip arp 10.15.2.10` alternates between `00:50:56:9a:11:22` (`Gi1/0/4`) and `3c:2a:f4:88:09:c1` (`Gi1/0/19`). What does this confirm?
- A.IEEE 802.3ad LACP hashing TCP sessions across dual NICs on the HR VM
- B.Duplicate IP 10.15.2.10 shared by the HR server and a printer✓
- C.Round-robin DNS alternating two distinct IPv4 A records for the HR hostname
- D.Spanning Tree root port flapping between Gi1/0/4 and Gi1/0/19 every minute
Correct answer: B
Two distinct MAC addresses (`00:50:56:...` VMware OUI on `Gi1/0/4` and `3c:2a:f4:...` on `Gi1/0/19`) overwriting each other in the router's ARP cache for `10.15.2.10`—combined with seeing a printer UI—proves a duplicate static IP conflict (Option B). Option A would share one logical LACP interface/host, Option D would flap a single MAC across trunks, and Option C involves multiple IPs rather than two MACs claiming one IP.
Question 10easy
A security camera mounted at a loading gate 148 meters from the wiring closet over one continuous unshielded Cat6 run intermittently loses link and drops from 1000BASE-T to 10BASE-T, even though a continuity wiremap tester shows pins 1-8 wired straight through (`T568B` at both ends). What explains this fault?
- A.Passing pin-to-pin wiremap continuity proves a Layer 4 RTSP port conflict
- B.Attenuation from exceeding the 100-meter twisted-pair channel limit✓
- C.Terminating T568B on both ends creates a crossover pinout that breaks Auto-MDIX
- D.Unshielded Cat6 copper is rated only for 100BASE-TX speeds regardless of length
Correct answer: B
IEEE 802.3 specifies a 100-meter maximum copper channel length (typically 90 m solid horizontal permanent link + 10 m patch cords) for twisted-pair Ethernet. At 148 meters, high-frequency signal attenuation and insertion loss degrade SNR even when DC pin-to-pin continuity tests pass—requiring fiber, an intermediate PoE extender/switch, or long-reach media converters (Option B). Option C, Option D, and Option A misdiagnose cabling standards.